Products
Low / Mid rise
Our Products
Elevators for Low and Mid-Rise Buildings
ACRA™ 2.0
Mini Machine Room (MMR)
- Machine room Mini Machine Room (MMR)
- Duty load 450~1600 kg
- Max. Stops 40
- Max. Rise 130cm
- Code EN81-1 / EN81-20
COMPACT DESIGN
Mini machine room technology eliminates machine room space and cost for greater architectural design freedom.
MAXIMIZED SPACE SAVINGS
Compact PMSM allows a smaller machine sheave,
reducing machine size and raising efficiency.


EMC (Electronic Magnetic Certificated)
- Globally designed and manufactured
- Lower vibration and better ride quality
- UCMP & ACOP certified
(Unintended Car Movement Protection) (Ascending Car Overspeed Protection)
VDI(Energy efficiency Certificate)

Globally designed and manufactured
- Lower vibration and better ride quality
- UCMP & ACOP certified
(Unintended Car Movement Protection) (Ascending Car Overspeed Protection)
E3 Policy
Main Safety Components

Safety Gear
Sigma Standard
24 times of System Braking
EN81 Standard
3 times of System Braking

Overspeed Governor
12 times of Dynamic Activation
EN81 Standard
3 times of Dynamic Activation

Oil Buffer
100 times of Impact Test
EN81 Standard
2 times of Impact Test

PU Buffer
1m/s(Std.)
Environment Test
- The industry-leading seal-star function to ensure safe rescue.
- More silent, adopt noiseless contactor.
- EMC compliance, non interference with other electromagnetic devices
SOLON® 2.0
MRL(Machine room-less)
The SOLON® 2.0 elevator requires only a hoistway, thanks to its compact machine and integrated controller neatly mounted on rail.
This true machine room-less design removes the need for a separate rooftop equipment space, reducing construction costs while maximizing architectural freedom and usable building area.
- Machine room-less
- Duty load 450~1050 kg
- Speed 1.0~1.75 m/s
- Max. Stops 31
- Max. Rise 80 m
- Code EN81-1 / EN81-20

- Globally designed and manufactured
- Lower vibration and better ride quality
- UCMP & ACOP certified(Unintended Car Movement Protection)
(Ascending Car Overspeed Protection) - Efficient and reliable performance
- More reliable and better EMC performance
- Lower brake noise

SOLON® 2.0
E3 Policy
Main Safety Components

Safety Gear
Sigma Standard
24 times of System Braking
EN81 Standard
3 times of System Braking

Overspeed Governor
12 times of Dynamic Activation
EN81 Standard
3 times of Dynamic Activation

Oil Buffer
100 times of Impact Test
EN81 Standard
2 times of Impact Test

PU Buffer
1m/s(Std.)
Environment Test
- The industry-leading seal-star function to ensure safe rescue.
- More silent, adopt noiseless contactor.
- EMC compliance, non interference with other electromagnetic devices
MUSE™ 2.0
MRL(Machine room-less)
MUSE™ 2.0 is Sigma’s flagship MRL model, widely used around the world.
The major difference from SOLON® 2.0 is that it uses a Coated Steel Belt instead of a wire rope. With the application of a high‑efficiency inverter and a PM (Permanent Magnet) motor, the system achieves excellent energy efficiency.
As a machine‑room‑less product, it enhances architectural design flexibility and contributes to improved building aesthetics.
MACHINE ROOM-LESS CONFIGURATION
The MUSE™ 2.0 elevator requires only a hoistway as it features a compact machine and controller that fit inside it. This eliminates the need for a machine room to house the elevator components on top of the building, resulting in lower construction expenses and freeing up rooftop space.
- Machine room-less
- Duty load 800~1600 kg
- Speed 1.0~2.5 m/s
- Max. Stops 40
- Max. Rise 120 m
- Code EN81-20

Ultra-compact Permanent Magnet Gearless Machine

Controller Regen System Energy efficiency
E3 Policy
Main Safety Components

Safety Gear
Sigma Standard
24 times of System Braking
EN81 Standard
3 times of System Braking

Overspeed Governor
12 times of Dynamic Activation
EN81 Standard
3 times of Dynamic Activation

Oil Buffer
100 times of Impact Test
EN81 Standard
2 times of Impact Test

PU Buffer
1m/s(Std.)
Environment Test
- The industry-leading seal-star function to ensure safe rescue.
- More silent, adopt noiseless contactor.
- EMC compliance, non interference with other electromagnetic devices